microtrack filtration

Adenocarcinoma adenoma anatomy bleeding cancer colon colonoscopy duodenum echocardiography emr endoscopy ent images esophagus for dental students for dentists gastroscopy Histopathology hysterectomy laparoscopy polyp polypectomy rectum robotic surgery stomach surgical education surgical technique surgical video case TUMOR ulcer varices
Number of Results
Sort by

Microtrack Filtration for Glaucoma

views: 2292 comments: 0
N/A

Microtrack filtration for glaucoma, my latest movie. There is slight variation - mixing 200 micron Fugo blade tip and 100 micron tip. The surgery is very easy, atraumatic and offers high rate of success.

Microtrack Filtration - First Attempt at One...

views: 3043 comments: 0
N/A

Considering that there are 70 to 80 million glaucoma patients in the world, there ought to be a simple procedure, that provides nothing more than a small drainage channel to control eye pressure. Attempt...

Failed Microtrack - Management

views: 3050 comments: 0
5

Failure is common in glaucoma surgery, though it is much less with Microtrack filtration, if you go with my experience. Still every time you operate a glaucoma patient, make sure to preserve the tissues,...

Juvenile Glaucoma - Microtrack Filtration, Follow...

views: 3910 comments: 0
N/A

Simplest way to tackle juvenile glaucoma, without destructive dissections and cautery etc. The lymphatics are saved, they are the drains for out-coming aqueous. One of the best ways to control worldwide...

Microtrack Filtration - Bleeding After Iridectomy

views: 3163 comments: 0
N/A

Bleeding occurred during the course of Microtrack filtration for a case of absolute glaucoma painful blind eye. It was managed easily.

Posterior Uveitis - Glaucoma - Microtrack Filtration

views: 3799 comments: 2
5

A young patient of posterior uveitis, undergoing treatment with steroids in vitreous, has uncontrolled glaucoma. Microtrack filtration is done as minimally invasive surgery for glaucoma.

Twice Failed Trabeculectomy - Microtrack Filtration

views: 3076 comments: 0
N/A

The management was easy - just made a Microtrack with 200 micron Fugo blade tip, near the edge of failed TRAB.

MTF in Neovascular Glaucoma - Bleeding During...

views: 2023 comments: 0
5

PXIOL present. A case of neovascular glaucoma. Microtrack filtration 2 tracks with 200 micron Fugo blade tip. Oblique incision for entry in to the anterior chamber, 1.5 mm wide, through which iridectomy...

Buphthalmos Surgery Complication - Management

views: 1693 comments: 0
N/A

A failed buphthalmos surgery case when re-operated had a vitreous prolapse. An alternate site was found at the opposite limbus to perform Microtrack filtration. Hopefully this shall work is all you can...

VR Surgery Case, Microtrack Filtration

views: 1999 comments: 0
N/A

A diabetic VR surgery case, with a PCIOL, IOP 40 mm. There is scarring around the limbus. Luckily proximal to the iridectomy, the conjunctiva can be pushed sufficiently close to the limbus, so that a...

Number of Results
Sort by