filtration
Microtrack Filtration in a Case of Traumatic...
A case of trauma accompanied by rupture of sphincter and dilatation of the pupil. There may be subluxation of the lens since the anterior chamber is deep. A 2 mm half thickness incision is made in the...
Results of phacoemulsification after microtrack...
In this video the results of phaco after microtrack filtration (MTF) glaucoma procedure are reported. Phaco was performed after 5 months after MTF. In early post operative after MTF patient had inner...
Failed Transciliary Filtration - Resurgery
The video presents a case of failed transciliary filtration (TCF). After some time the procedure must be repeated. A 500 micron Fugo blade tip is utilized to complete the procedure. We can see the 3D...
Transciliary Filtration - Vitreoretinal Case
The video presents the transciliary filtration which is followed by opening of the anterior chamber so that the sillicone oil can be washed out. The operator deposits Mitomycin 0,01% under the conjunctiva....
Transciliary Filtration - Mitomycin
The video displays the transciliary filtration technique. Fugo blade is used and in the end Mitomycin 0,01% is injected under the conjuntiva.
Neovascular Glaucoma - Transciliary Filtration
The video shows the procedure of transciliary filtration. First the conjuctiva is balooned using a viscoelastic substance. Next the cornea is incised and HEALON® is injected in the anterior chamber and...
Filtration channel in anridia
The video presents making of filtration channel (200 micron width and 1.5 mm legth) in a patient with anridia. 100 micron Fugo blade is used in the procedure.
Uveitic glaucoma- transciliary filtration
The video presents the procedure of transciliary filtration in the treatment of severe uveitic glaucoma.
Transciliary filtration in the surgery of acute...
The video presents the usage of 500 micron Fugo blade tip in transciliary filtration while the surgery of acute glaucoma.
Microtrack filtration of uveitic glaucoma
The video presents a 100 micron Fugo blade tip in the procedure of microtrack filtration in a patient with uveitic glaucoma.
Transconjunctival filtration with bleeding
The video shows the procedure of transconjunctival transciliary filtration after which bleeding from the posterior chamber occurred. To stop bleeding irrigation is done.
Transciliary filtration
The video presents microtrack filtration which caused choroidal detachment. The 300 micron Fugo blade tip is used for entering the anterior chamber through the conjunctiva and sclera
Pseudophakic glaucoma treatment with microtrack...
The video presents the procedure of microtrack filtration with the use of 100 micron Fugo blade tip in pseudophakic glaucoma.
Microtrack filtration in buphthalmos
The video presents the use of microtrack filtration with 100 micron tip Fugo blade in a patient with buphthalmos.